Backed by over 45 years of expertise in refrigeration, the Rinnai Commercial Hot Water Heat Pump delivers high-efficiency performance while withstanding Australia’s harsh climate.

Constructed from heavy-duty galvanised steel, it features corrosion-resistant epoxy-coated coils, an integrated primary circulation pump, and a wide ambient temperature operating range. Using the environmentally friendly R513A refrigerant with zero Ozone Depletion Potential and 56% lower Global Warming Potential (GWP) than R134A, it achieves a class-leading Coefficient of Performance (COP).

Smart commissioning and diagnostics via a mobile app make setup and maintenance simple, while flexible installation options and an optional back-up electric heating function ensure reliable operation in any setting.

Return to COMMERCIAL home

Locate Your Nearest Stockist

NOTE: Rinnai does not sell directly to the public. Our products are available only through third-party stockists and installers.

Specialist

Dealer

Retailer

Trade

Flame Fire Specialist

Climate Specialist

Dealer

Retailer

Trade

Ideal for apartment blocks, hotels and student accommodation

Heavy duty galvanised steel construction

Integrated primary circulation pump

Multiple installation configuration options

Class leading efficiency

  • Designed with 45+ years of APAC refrigerated experience
  • 56% lower Global Warming Potential (GWP) than R134A*
  • Zero Ozone Depletion Potential (ODP) R513A refrigerant

Features

  • Heavy duty galvanised steel construction
  • Wide ambient temperature operating range
  • Class leading Coefficient of Performance (COP)
  • Integrated primary circulation pump
  • Easy commissioning/diagnostics via smart phone app
  • Multiple installation configuration options
  • Optional back-up electric heating function for low ambient boost
  • Corrosion resistant Epoxy coated coils as standard

Custom options available

  • Full 316 stainless steel cabinets
  • High static fans for plant room applications
  • Blygold treated coils for extra corrosion protection
  • Circulation pump deletion option for retrofits
  • Ducted version for internal installation

The product information on this website (comprising product brochures, warranty information, installation manuals, diagrams, specifications and representations) relates to current products. This information may be different for superseded products. For superseded products please contact Rinnai to confirm product information.

*R513A Prime Refrigerant is a low Global Warming Potential (GWP) hydrofluoroolefin (HFO) blend designed as an environmentally friendly alternative to R134a, suitable for medium and high temperature refrigeration applications.

Rinnai – Commerical Heat Pump Units CHP020 CHP040
Product Dimensions Height mm 1162 1442
Width 730 850
Length 1550 2050
Heating Capacity [1] kW 20.0 39.5
Electrical Supply V / Ph/Hz 400 – 415 / 3 / 50 400 – 415 / 3 / 50
Power Input [2] kW 4.7 9.6
COP [1] 4.27 4.10
Rated Load Amps Per Phase [3] A 14.5 30
Full Load Amps Per Phase [4] 17.5 35
Minimum Circuit Size (Per Phase) 20 40
Conductor Cross-sectional Area Refer to AS / NZS 3000 & AS / NZS 3008
Recovery Rate [1] L / Hr 344 680
Operating Range (Ambient)[1] °C 0 – 50
Compressor Scroll
Compressor Quantity 1
No. of Refrigeration Circuits 1
Refrigerant Type R513A
Outdoor Fans Hybrid Axial
Outdoor Fan Quantity 2
Outdoor Fan Speed Control Type  
Outdoor Coil Cu/Al
Outdoor Coil Fin treatment Black Epoxy
Outdoor Airflow L / s 2500 4470
Water / Refrigerant Heat Exchanger Type Double Wall Stainless Steel
Water / Refrigerant Heat Exchanger Quantity 1 2
Rated Sound Power Level dB(A) 66.6 @ 1m 68.7 @ 1m
Pressure Level 53 @ 3m 55 @ 3m
Cabinet IP Rating IPX4
Water Pump Model Grundfos CM 3-2 Gundfos CM 10-1
Water Pump Electrical Supply V / Ph / Hz 240 / 1 / 50
Outlet Water Head m 10 8
Water Connections MBSP 32 50
Rated Water Pressure kPa 1000
Maximum Supply Water Pressure 800
Pressure Limits – ECV Fitted Fit PLV if mains pressure exceeds 680
Recommended PLV Pressure Rating 500
Pressure Limits – ECV Not Fitted Fit PLV if mains pressure exceeds 800
Recommended PLV Pressure Rating 500
Maximum Water Temperature Setting °C 65
Nominal Weight [3] kg 236 360

With our policy of continuous improvement, we reserve the right to change, or discontinue at anytime, specifications or designs without notice.
Note: All images contained within this brochure are for illustrative purposes only, the colours and finishes of the products featured are as close to the respective product range as photographic lighting and printing processes allow. The heat pump must be installed in a freely ventilated space in accordance with the nominated installation clearances. Insufficient ventilation may impede product performance and efficiency.

[1] Test Condition: 20°C ambient / 60% RH. 39°C water in / 45°C water out.
[2] Water pump power is not included.
[3] R.L.A – Run Load Amps are based on current drawn at nominal conditions @ 65°C water temp
.
[4] F.L.A – Full Load Amps are based on overload settings (max current) of all compressor,fan motor(s) and pump(s) @65°C water temp.
[5] For base model only. Factory options will vary.

- Consumer Consumer
  • Commercial Heat Pump Specification Guide
  • Commercial Heat Pump Operation and Installation Manual
  • Commercial Heat Pump 3HP Auxiliary Relay Box Operation and Installation Manual
  • Commercial Heat Pump (CHP020, CHP040) Error Codes
  • Commercial Hot Water Warranty Booklet
+ Trade Trade
+ RFA diagrams
  • Plans - CHP020VP Commercial Heat Pump (RFA)
  • Plans - CHP040VP Commercial Heat Pump (RFA)
+ Photos Photos

Book a Service
/ Repair / Warranty Assessment

Looking for support?
Please get in touch and let us help.

Find a Stockist

We'll help you find a Rinnai stockist so you receive the right advice and product, as locally as possible.