Rinnai Inverter Split Ducted Air Conditioner R410A

Ducted Air R410A 17.0kW

Discontinued

  • Warranty 03 - 7 year Residential
  • WiFi

Advanced ducted comfort.

The Rinnai 17.0kW Ducted Air Conditioning R410A System offers powerful yet discreet climate control, using advanced inverter technology and energy-efficient components to maintain consistent comfort throughout the home.

View replacement: Ducted Air 18.0kW

Model
16.7-17.5kWOutput
1100L/sAirflow
  • Warranty 03 - 7 year Residential
  • WiFi

Highlights

  • Whole home or multi-zone ducted air conditioning
  • Responds rapidly to changing conditions, providing fast and precise temperature control
  • 3D DC Inverter ducted system
  • Efficient ducted heating and cooling
  • Powerful output for larger homes
  • Quiet ducted reverse cycle air conditioning
  • Easy to use control system
  • Wired programmable controller / Optional Wi-Fi and Remote access
  • 7 year warranty*

Specifications

Rinnai – System Model No

07 10 12 14 17

Nominal Capacity

7 10 12 14 17 kW

Power Supply

To Outdoor Unit

220~240 – 1 – 50 V- Ph-Hz

Maximum Input

Power

3000 3900 5500 5500 6000 W

Current

16.0 21.0 26.0 26.0 30.0 A

Recommended Circuit Breaker Size

20 25 32 32 40 A

Cooling

Rated Capacity

7.1 10.3 12.7 14.2 16.7 kW

Capacity Range

2.8 ~ 8.4 4.0 ~ 12.5 5.0 ~ 15.0 5.6 ~ 16.1 6.8 ~19.0 kW

Rated Input Power

2066 3109 3821 4147 4883 W

Rated Input Current

10.0 13.7 16.9 18.5 21.3 A

Annualised Energy Efficiency Ratio [AEER]1

3.37 3.29 3.30 3.40 3.39 W / W

Heating

Rated Capacity

8.2 10.3 14.4 17.3 17.5 kW

Capacity Range

3.0 ~ 9.0 4.2 ~ 12.5 5.0 ~17.0 5.8 ~19.0 7.0 ~ 20.0 kW

Rated Input Power

2383 2809 3863 4427 4417 W

Rated Input Current

11.3 12.4 16.9 19.5 19.3 A

Annual Coefficient of Performance [ACOP]2

3.40 3.63 3.70 3.87 3.94 W / W

1. AEER: The Annualised Energy Efficiency Ratio (AEER) measures a cooling system’s efficiency by comparing its total cooling output to the electricity it consumes, including standby power.
2. ACOP: The Annual Coefficient of Performance (ACOP) measures a heater’s efficiency by comparing its total heating output to the electricity it consumes, including standby power.

Rinnai – System Model No

07 10 12 14 17

Nominal Capacity

7 10 12 14 17 kW

Power Supply

To Outdoor Unit

220~240 – 1 – 50 V- Ph-Hz

Maximum Input

Power

3000 3900 5500 5500 6000 W

Current

16.0 21.0 26.0 26.0 30.0 A

Recommended Circuit Breaker Size

20 25 32 32 40 A

Cooling

Rated Capacity

7.1 10.3 12.7 14.2 16.7 kW

Capacity Range

2.8 ~ 8.4 4.0 ~ 12.5 5.0 ~ 15.0 5.6 ~ 16.1 6.8 ~19.0 kW

Rated Input Power

2066 3109 3821 4147 4883 W

Rated Input Current

10.0 13.7 16.9 18.5 21.3 A

Annualised Energy Efficiency Ratio [AEER]1

3.37 3.29 3.30 3.40 3.39 W / W

Heating

Rated Capacity

8.2 10.3 14.4 17.3 17.5 kW

Capacity Range

3.0 ~ 9.0 4.2 ~ 12.5 5.0 ~17.0 5.8 ~19.0 7.0 ~ 20.0 kW

Rated Input Power

2383 2809 3863 4427 4417 W

Rated Input Current

11.3 12.4 16.9 19.5 19.3 A

Annual Coefficient of Performance [ACOP]2

3.40 3.63 3.70 3.87 3.94 W / W

1. AEER: The Annualised Energy Efficiency Ratio (AEER) measures a cooling system’s efficiency by comparing its total cooling output to the electricity it consumes, including standby power.
2. ACOP: The Annual Coefficient of Performance (ACOP) measures a heater’s efficiency by comparing its total heating output to the electricity it consumes, including standby power.

Resources

Brochure

Ducted Air Conditioner Brochure

Download
Specification

Ducted Air Conditioner Operation Manual

Download
Specification

Ducted Air Conditioner Smart Port (Wi-Fi) Wireless Smart Kit Operation Manual

Download
Specification

Ducted Air Conditioner Wired Remote Controller Operation Manual

Download
Warranty

Air Conditioner Warranty Booklet

Download

Disclaimer / Footnotes

Product codes: DINLR17Z72 DONSR17Z72

Need help finding the right product?

Our team can help you compare products, confirm installation requirements and connect you with a stockist.