Ducted Air R32 7.0kW
Discontinued
An advanced ducted reverse cycle air conditioner.
Highlights
- Up to 8 individual zones
- AC unit control
- 5% airflow control adjustments
- ‘Filter Clean’ reminder with adjustable frequency
- Slimline design
- Rapid temperature control with personalised favourites, programmable schedules, and a sleep timer
- Programmable controller
- Reduced operational costs
- Quiet operation
- Zoning option
Specifications
Indoor Unit | DINLR07B1 DINLR09B1 DINLR11B1 DINLR13B1 DINLR15B1 DINLR18B1 | |
|---|---|---|
Rated Input | 90 250 560 560 560 420 W | |
Rated Current | 1.6 2.5 2.5 3.0 3.0 3.0 A | |
Airflow (With Filter) | High Speed | L / s (ESP) 480 (100 Pa) 625 (150pa) 710 (150Pa) 1050 (150Pa) 1050 (150Pa) 1080 (150Pa) |
Airflow (Minimum) | 140 190 190 250 250 410 | |
Maximum External Static Pressure (ESP)3 | 160 160 200 200 200 200 Pa | |
Noise Level | Sound Pressure @ 1.4m | 38.5 / 35.5 / 32.5 45 / 42 / 39.5 39 / 37 / 34.5 46.5 / 43.5 / 40 46.5 / 43.5 / 40 53 / 49.5 / 45.3 dB(A) |
Dimensions | Net | 249 x 1100 x 774 249 x 1360 x 774 380 x 1200 x 625 380 x 1200 x 625 380 x 1200 x 625 440 x 1400 x 858 mm |
Packing | 315 x 1305 x 805 320 x 1570 x 805 450 x 1485 x 675 450 x 1485 x 675 450 x 1485 x 675 515 x 1605 x 910 mm | |
Weight | Net | 32 40 53 53 53 81 kg |
Gross | 38.5 48 62 62 62 92 kg | |
Duct Connections | Supply Air | 175 x 926 175 x 1186 253 x 1000 253 x 1000 253 x 1000 385 x 1188 mm |
Return Air | 228 x 1001 228 x 1261 334 x 1145 334 x 1145 334 x 1145 385 x 1188 mm | |
Condensate Drain Pipe Outer Diameter | 25 mm | |
Refrigerant Piping | Liquid / Gas Connections | 9.5 / 15.9 9.5 / 19.0 mm |
Moisture Removal | 2.0 2.5 2.7 3.0 3.0 3.5 L / h | |
Controller | Type | Wired Programmable Controller with Wi-Fi Control |
Operating Range | Cooling | 17 ~ 32 °C |
Heating | 0 ~ 30 °C | |
3. ESP: External Static Pressure refers to the level of resistance the blower fan in an HVAC system must overcome to push air through ductwork, filters, and dampers.
Indoor Unit | DINLR07B1 DINLR09B1 DINLR11B1 DINLR13B1 DINLR15B1 DINLR18B1 | |
|---|---|---|
Rated Input | 90 250 560 560 560 420 W | |
Rated Current | 1.6 2.5 2.5 3.0 3.0 3.0 A | |
Airflow (With Filter) | High Speed | L / s (ESP) 480 (100 Pa) 625 (150pa) 710 (150Pa) 1050 (150Pa) 1050 (150Pa) 1080 (150Pa) |
Airflow (Minimum) | 140 190 190 250 250 410 | |
Maximum External Static Pressure (ESP)3 | 160 160 200 200 200 200 Pa | |
Noise Level | Sound Pressure @ 1.4m | 38.5 / 35.5 / 32.5 45 / 42 / 39.5 39 / 37 / 34.5 46.5 / 43.5 / 40 46.5 / 43.5 / 40 53 / 49.5 / 45.3 dB(A) |
Dimensions | Net | 249 x 1100 x 774 249 x 1360 x 774 380 x 1200 x 625 380 x 1200 x 625 380 x 1200 x 625 440 x 1400 x 858 mm |
Packing | 315 x 1305 x 805 320 x 1570 x 805 450 x 1485 x 675 450 x 1485 x 675 450 x 1485 x 675 515 x 1605 x 910 mm | |
Weight | Net | 32 40 53 53 53 81 kg |
Gross | 38.5 48 62 62 62 92 kg | |
Duct Connections | Supply Air | 175 x 926 175 x 1186 253 x 1000 253 x 1000 253 x 1000 385 x 1188 mm |
Return Air | 228 x 1001 228 x 1261 334 x 1145 334 x 1145 334 x 1145 385 x 1188 mm | |
Condensate Drain Pipe Outer Diameter | 25 mm | |
Refrigerant Piping | Liquid / Gas Connections | 9.5 / 15.9 9.5 / 19.0 mm |
Moisture Removal | 2.0 2.5 2.7 3.0 3.0 3.5 L / h | |
Controller | Type | Wired Programmable Controller with Wi-Fi Control |
Operating Range | Cooling | 17 ~ 32 °C |
Heating | 0 ~ 30 °C | |
3. ESP: External Static Pressure refers to the level of resistance the blower fan in an HVAC system must overcome to push air through ductwork, filters, and dampers.
Disclaimer / Footnotes
Product codes: DONSR07B1 DINLR07B1


&w=3840&q=75)