HOTFLO & CENTURION

specifications

 

All Rinnai Electric Water Heaters Are Single Element Only.

*Available May/Jun 07.

**A 500 kPa PLV is supplied with all Hotflo tanks. It must be fitted if the maximum supply pressure exceeds the limits shown. If the maximum supply pressure is within the limits shown, fitting of this valve is optional. It is recommended that the PLV is fitted in all installations as it aids water and energy conservation.

    HOTFLO CENTURION
  Rated Capacity (Litres) 40* 80 125 160 200 250 315 160 200 315
Weight Empty (kg) 24 48 62 75 98 107 117 39 49 59
Heating Elements Available (kW) - - - - - - - 1.8 1.8 1.8
2.4 2.4 2.4 2.4 - - - 2.4 2.4 2.4
3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
- - - - 4.8 4.8 4.8 4.8 4.8 4.8
DIMENSIONS (mm) Overall Height A 665 900 1245 1530 1825 1265 1510 1170 1690 2070
Overall Width inc’ PTR B 470 590 590 590 590 760 760 740 740 740
Tank Diameter C 395 515 515 515 515 685 685 600 600 600
Outlet Height D 470 683 1020 1310 1605 985 1200 960 1460 1860
Inlet Height E 75 225 225 225 225 260 260 270 270 270
Electrical Connection Height F 125 155 155 155 155 155 155 225 225 225
Hot Return (Centurion Only) G - 335 335 335
  Relief Valve Setting (kPa) 1000 850
Expansion Control Valve Setting 850 700
MAX SUPPLY PRESSURE (kPa) With Expansion Control Valve 680** 550**
Without Expansion Control Valve 800** 680**
When these pressures are exceeded, install the Pressure Limiting Valve (PLV) supplied with the Tank  
  Water Connections RP ¾ 20mm
  Ingress Protection Rating (AS1939) IPX4
  Power Supply AC 240 V 50 Hz


ROOFMASTER

specifications
    PLUS PRESTIGE COIL
  Rated Capacity (Litres) 160 250 315 250 315 315
Rated Capacity Connected to Solar (L) - - - 280 370 370
Weight Empty (kg) 26 32 37 34 42 59
DIMENSIONS Overall Height A 525 725 900 725 900 900
Tank Diameter B 865 865 865 865 865 865
Height - Hot Water Outlet C 335 530 710 530 710 710
Height - Cold Water Inlet D 485 700 875 700 875 875
Overall Top Width (inc Head Tank) E 1020 1020 1020 1020 1020 1020
Combustion Heater (Hot Flow) F   325 415 415
Combustion Heater (Cold Return) G 85 85 85
Solar Collector Flow Height H 535 715 715
Solar Collector Return Height J 535 715 715
Coil - Cold Inlet Connection K   140
Coil - Hot Outlet Connection L 670