Selection & Technical Data
| Model Identification |
HD200e V2630WC |
HD250e V3237WC |
HD200i V2632FFUC |
| Star Rating |
5.2 |
5.3 |
5 .0 |
| Installation |
External |
External |
Internal |
| Gas Consumption MJ/h (Hi / Low) |
NG
LPG |
199/23
199/23 |
250/21
250/21 |
195/16
195/16 |
| Gas Pressures Required kPa |
NG
LPG |
1.13 - 2.75
2.75 |
1.13 - 2.75
2.75 |
1.13 - 2.75
2.75 |
| Dimensions |
mm |
Width
Height
Depth |
350
530
194 |
470
600
244 |
350
600
224 |
| Weight |
|
15 kg |
29 kg |
22 kg |
| Water Flow |
L/min |
minimum |
2.4 |
2.4 |
2.4 |
| Antifrost |
Standard |
Optional |
| Flue System |
(FF=Forced Flued) |
FF external |
FF external |
FF internal |
| Default Temp Settings |
°C |
with remote |
40, 42, 50, 55, 60, 65, 75 |
| °C |
without remote |
40, 42, 50, 55, 60, 65, 75, 85 |
40, 42, 50, 55, 60, 65, 75, 85, (95) |
40, 42, 50, 55, 60, 65, 75, 85 |
| Burner System |
Low Nox, Multi Stage - Fully Modulating |
| Connections |
gas supply, cold, hot |
R 3/4 - 20A (right), R 3/4 - 20A (centre), R 3/4 - 20A (left) |
| Maximum Water Operating Pressure kPa |
1000 |
| Maximum Outlet Temperature |
85°C |
95°C |
85°C |
| Electrical Consumption (Watts) Normal / Standby / Anti frost protection |
65 / 6 / 100 |
83 / 12 / 100 |
80 / 7.5 / 100 |
| Ignition System |
Direct electronic ignition with automatic flame sensing (230 / 240 V) |
| AGA Thermal Efficiency Rating |
80.8% |
81.1% |
81.1% |
| kW Output |
45.6 |
58.9 |
44.3 |
| Power Supply |
Appliance |
AC 240 Volts 50 Hz (10 Amp power point required) |
| Remote Control |
DC 12 Volts (Digital) |
| Colour |
Titanium |
Rinnai reserves the right to modify specifications
|
|