Selection & Technical Data

techImage
Model Identification HD200e V2630WC HD250e V3237WC HD200i V2632FFUC
Star Rating 5.2 5.3 5 .0
Installation External External Internal
Gas Consumption MJ/h (Hi / Low) NG
LPG
199/23
199/23
250/21
250/21
195/16
195/16
Gas Pressures Required kPa NG
LPG
1.13 - 2.75
2.75
1.13 - 2.75
2.75
1.13 - 2.75
2.75
Dimensions mm Width
Height
Depth
350
530
194
470
600
244
350
600
224
Weight   15 kg 29 kg 22 kg
Water Flow L/min minimum 2.4 2.4 2.4
Antifrost Standard Optional
Flue System (FF=Forced Flued) FF external FF external FF internal
Default Temp Settings °C with remote 40, 42, 50, 55, 60, 65, 75
°C without remote 40, 42, 50, 55, 60, 65, 75, 85 40, 42, 50, 55, 60, 65, 75, 85, (95) 40, 42, 50, 55, 60, 65, 75, 85
Burner System Low Nox, Multi Stage - Fully Modulating
Connections gas supply, cold, hot R 3/4 - 20A (right), R 3/4 - 20A (centre), R 3/4 - 20A (left)
Maximum Water Operating Pressure kPa 1000
Maximum Outlet Temperature 85°C 95°C 85°C
Electrical Consumption (Watts) Normal / Standby / Anti frost protection 65 / 6 / 100 83 / 12 / 100 80 / 7.5 / 100
Ignition System Direct electronic ignition with automatic flame sensing (230 / 240 V)
AGA Thermal Efficiency Rating 80.8% 81.1% 81.1%
kW Output 45.6 58.9 44.3
Power Supply Appliance AC 240 Volts 50 Hz (10 Amp power point required)
Remote Control DC 12 Volts (Digital)
Colour Titanium

Rinnai reserves the right to modify specifications